Chemical storage tank linings
Stored chemicals attack tank floors and the floor-to-shell weld, thinning steel where stagnant product settles and the old lining has worn through.
The need for chemical storage tank linings
BHI Coatings performs chemical storage tank linings across Alvin and the Texas Gulf Coast. Stored chemicals settle and stagnate against the tank floor, and wherever the old lining has worn through, the steel starts thinning. The floor-to-shell weld goes first, because that seam concentrates stress and product attack along one line. A leak there costs inventory, an environmental report, and an unplanned shutdown.
How BHI Coatings does chemical storage tank linings
We blast the interior to the required profile, then lay a cold-cure lining down as one continuous film across floor, weld, and shell. The Belzona 4341 system bonds to the prepared steel without hot work, so there are no welds to recoat and no heat soak on the vessel. It all cures at ambient temperature inside the climate-controlled conditions our crew maintains on site.
Typically applied with Belzona 4341, Belzona 1391T, matched to the service conditions.
The tank goes back into service under a joint-free barrier, with the corroded areas covered and the floor weld protected as part of the same film.

More Tank & Containment Lining applications
Bund walls spall from the inside out, exposing rebar and opening cold-joint cracks until the wall no longer holds its rated volume.
Learn more →Digester lining and repairKraft digesters carry hot sulfate-rich liquor that thins linings and corrodes every weld and access port over a single campaign.
Learn more →Evaporator, de-aerator and autoclave liningEvaporators, de-aerators, and autoclaves run hot and wet, so conventional linings break down and the shell corrodes at welds and tube zones.
Learn more →Food and beverage hygienic liningsTanks and troughs in food and beverage plants face daily caustic wash-down and hot CIP cycles that ordinary coatings cannot pass on audit.
Learn more →Potable-water tank liningInternal corrosion in drinking-water tanks and pump components forces a choice between costly replacement and a certified recoat.
Learn more →Process vessel and drum liningsProcess vessels, knock-out drums, and clarifiers corrode at welds and access ports where the product chemistry thins the original liner.
Learn more →All 12 in Tank & Containment LiningThe whole capability in one place, with the work grouped.
See the capability →Contact BHI Coatings
Have equipment that needs to stay in service?
Tell us what is failing. We respond quickly, and we offer 24-hour on-call service.